TPM Site Configuration
TPM Site configuration objects are required to connect other configuration objects for a Site (or subordinate levels) in the ISA-95 Model with Timezone Availability Tracker objects in the I/O Model.
This connection is a prerequisite for several other OEE Configuration Objects to work properly.
To keep track of the quality of the individual connections, each Site in the ISA-95 Equipment Model needs to have its own TPM Site Configuration object configured, even if some of them are located in the same timezone.
| For redundancy reasons, several Connector objects which are available in the site context should be linked up to the matching TPM Site Configuration object. |
This configuration object type can be created on a Site level.
Creating a TPM Site Configuration Object
To create a TPM Site Configuration object …
1 Right-click on the Site object in the ISA-95 Equipment Model tree and select .
2 In the Create TPM Site Configuration wizard, provide a suitable Object Name and an optional Object Description.
3 Then click on the table icon for Timezone Reference property.
4 A link to each Timezone And Availability Tracker object on this site has to be added to the Timezone Reference table.
To do this, click on the … button in the Timezone Reference column
a and select the Timezone And Availability Tracker object from the I/O Model Scope.
b Then click OK.
5 When references are set to all intended Timezone And Availability Tracker objects, click OK to confirm and close the dialog.
6 Back in the Create TPM Site Configuration, click Create.
The new TPM Site Configuration object is added to the ISA-95 Equipment Model tree.
Linking the TPM Site Configuration to the OEE Equipment Monitor
To specify the TPM Site Configuration which shall be taken into account by the OEE Equipment Monitor, …
1 Go to the Configuration Options section in the monitor’s properties and click on … for the Site Configuration Source to open the object picker in the ISA-95 Model.
2 Select the intended Site Configuration Object.
3 Click OK to confirm and close the dialog and Apply the changes to the properties.