TPM Not Scheduled Configuration

TPM Not Scheduled objects are used to inform the OEE Equipment Monitor object about when and why an equipment was not scheduled for production.

This configuration object type can be created on a Site, Area and Cell level.

A fully configured Site Configuration object is required for this configuration object to work properly.

Creating a TPM Not Scheduled Configuration Object

To create a TPM Not Scheduled Configuration object, in the ISA-95 Equipment Model right-click on the intended parent object of one of the types listed above ('The OEE Demo Cell' in the example) and select Admin  New  TPM  Not Scheduled Configuration to open the Create Not Scheduled Configuration wizard.

Enter a suitable name and an optional description for the object. Then click the table icon for the 'Not Scheduled Time Table' property.

Not Scheduled Configuration
Figure 1. Not Scheduled Configuration

Add a row for each period of time which is not scheduled, setting the start and end time and selecting the Reason and Detail from the drop down lists. Optionally you can add a Comment for this period.

Old data should be deleted from the table to keep them as small as possible.
The Not Scheduled Configuration Table
Figure 2. The Not Scheduled Configuration Table

When you have entered all periods, where this section of the enterprise is not meant to be scheduled, click OK to close the table and Create to create the Not Scheduled Configuration object in the ISA-95 Model.

In this example, the object was created for 'The OEE Demo Cell' so this configuration object is shown underneath this cell object.

The New Not Scheduled Configuration Object in the ISA-95 Model
Figure 3. The New Not Scheduled Configuration Object in the ISA-95 Model

Linking the TPM Not Scheduled Configuration to the OEE Equipment Monitor

To specify the TPM Not Scheduled Configuration which shall be taken into account by the OEE Equipment Monitor, go to the Configuration Options section in the monitor’s properties and click on …​ for the Not Scheduled Configuration Source to open the object picker in the ISA-95 Model.

Setting the Not Scheduled Configuration Source
Figure 4. Setting the Not Scheduled Configuration Source

Select the intended Not Scheduled Configuration Object from the ISA-95 Model.

Linking the TPM Not Scheduled Configuration to the OEE Equipment Monitor
Figure 5. Linking the TPM Not Scheduled Configuration to the OEE Equipment Monitor

Click OK to confirm your selection and close the dialog and Apply the changes to the properties.

Configuring Recurring Not-Scheduled Times

Not-Scheduled Times which recur on a weekly basis can be configured in the Not Scheduled Recurrent Time Table property.

1 Click the table icon to open the Table Property Grid display.

2 To create a new period of not-scheduled times, in the row preceded with the '+' icon.

3 For the Day Start colum, select the weekday on which the not-scheduled period begins from the drop-down list.

4 In the Start Time column, specify the start time of the not-scheduled period.

5 For the Day End colum, select the weekday on which the not-scheduled period ends from the drop-down list.

6 In End Time column, specify the end time of the not-scheduled period.

7 In Valid From column specify the begin of the period during which the not-scheduled times defined in the first four colums is valid.

8 In Valid To column specify the end of the period during which the not-scheduled times defined in the first four columns is valid.

9 Click OK to close the Table Property Grid display, then click Apply to confirm the property changes.