TPM Site Configuration

TPM Site configuration objects are required to connect other configuration objects for a Site (or subordinate levels) in the ISA-95 Model with Timezone Availability Tracker objects in the I/O Model.

This connection is a prerequisite for several other OEE Configuration Objects to work properly.

To be able to keep track of the quality of the individual connections, each Site in the ISA-95 Equipment Model needs to have its own TPM Site Configuration object configured, even if some of them are locate in the same timezone.

For redundancy reasons, several Connector objects which are available in the site context should be linked up to the matching TPM Site Configuration object.

This configuration object type can be created on Site level.

Creating a TPM Site Configuration Object

To create a TPM Site Configuration object, right click on the Site object in the ISA-95 Equipment Model tree () and select Admin  New  TPM  TPM Site Configuration.

In the Create TPM Site Configuration wizard, provide a suitable Object Name and -optionally- Object Description.

Then click on the table icon for Timezone Reference.

Creating a New TPM Site Configuration Object
Figure 1. Creating a New TPM Site Configuration Object

For each Timezone And Availability Tracker object on this site, add a link to the Timezone Reference table and click on the …​ button in the Timezone Reference column to select the Timezone And Availability Tracker object from the I/O Model and click OK.

Selecting Timezone And Availability Tracker Objects
Figure 2. Selecting Timezone And Availability Tracker Objects
The Timezone Reference Table
Figure 3. The Timezone Reference Table

When references are set to all intended Timezone And Availability Tracker objects, click OK to confirm and close the dialog. Back in the Create TPM Site Configuration click Create.

The new TPM Site Configuration object is added to the ISA-95 Equipment Model tree.

The New Site Configuration Object in the ISA-95 Model
Figure 4. The New Site Configuration Object in the ISA-95 Model

Linking the TPM Site Configuration to the OEE Equipment Monitor

If no Site Configuration Source is configured in its Configuration Options, the OEE Equipment Monitor will use the very first Site Configuration object, which it finds when traversing the ISA-95 Equipment Model tree upwards.

To specify the TPM Site Configuration which shall be taken into account by the OEE Equipment Monitor, go to the Configuration Options section in the monitor’s properties, click on …​ for the Site Configuration Source to open the object picker in the ISA-95 Model.

Setting the Site Configuration Source
Figure 5. Setting the Site Configuration Source

Select the intended Site Configuration Object.

Linking the TPM Site Configuration to the OEE Equipment Monitor
Figure 6. Linking the TPM Site Configuration to the OEE Equipment Monitor

Click OK to confirm and close the dialog and Apply the changes to the properties.